XDF
1.110000

DO NOT HAND EDIT!!!! (Trust me)

%%HEADER%%
	001000 FileVers         ="1.0 "
	001005 DefTitle         ="Translator Pro"
	001007 DescSize         =0xF
	001006 Desc             ="For version 4.8"
	001010 Author           ="Bob Bailey, Mark Mansur"
	001030 BinSize          =0x300
	001035 BaseOffset       =0
	001200 ADSAssoc         ="..\\DataStreams\\Tpro4800.ads"
	001225 ADSCheck         =0x10421
	001300 GenFlags         =0x0
	001325 ModeFlags        =0x0
%%END%%

%%TABLE%%
	000002 UniqueID         =0x4EA1
	040005 Title            ="AFR Tracking"
	040011 DescSize         =0xB
	040010 Desc             ="AFR vs RPM"
	040100 Address          =0x176
	040200 ZEq              =X/10,TH|0|0|0|0|
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0x7
	040320 XUnits           ="AFR"
	040325 YUnits           ="AFR"
	040330 ZUnits           =""
	040350 XLabels          =2000,3000,4000,5000,6000,7000,8000
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =A/F Ratio
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040425 YALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x1554
	020005 Title            ="Vehicle Select"
	020011 DescSize         =0x26
	020010 Desc             ="Selects system mode based on vehicle."
	020020 Units            =""
	020100 Address          =0x110
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x3D
	020005 Title            ="Number of Cylinders"
	020011 DescSize         =0x60
	020010 Desc             ="Number of cylinders, assuming a 4-stroke engine.\r\nLS1 cars need to set this to 4               "
	020020 Units            =" "
	020100 Address          =0x111
	020200 Equation         =X*2,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6D68
	020005 Title            ="Displacement"
	020011 DescSize         =0x1E
	020010 Desc             ="Engine displacement in Liters"
	020020 Units            ="Liter"
	020100 Address          =0x112
	020200 Equation         =X/25,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x243D
	020005 Title            ="Airflow Source"
	020011 DescSize         =0x84
	020010 Desc             ="00 Speed Density\r\n01 Speed Density (without IAT/Density)\r\n10 MAF Input (with User Tune)\r\n11 MAF Input (with User Tune and VE table)"
	020020 Units            ="Select"
	020100 Address          =0x113
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x3
	020300 ALDLObj1         =0x1D
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6D92
	020005 Title            ="Manifold pressure source"
	020011 DescSize         =0x7F
	020010 Desc             ="The input/sensor used to sense manifold pressure.\r\n0 - GM 3Bar\r\n1 - AEM 3.5Bar\r\n2 - AEM 5Bar\r\n3 - GM 2Bar\r\n4 - Motorola 2.5Bar"
	020020 Units            =""
	020100 Address          =0x114
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020300 ALDLObj1         =0xB
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x3FC
	020005 Title            ="Load Source"
	020011 DescSize         =0x7D
	020010 Desc             ="Determines how load is calculated.  Load is used to select the low/mid/hi tune settings, and control Part Throttle Tracking."
	020020 Units            =""
	020100 Address          =0x115
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x3
	020300 ALDLObj1         =0x10
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x3BF7
	020005 Title            ="Barometer Comp Mode"
	020011 DescSize         =0x75
	020010 Desc             ="Mode of Barometer compensation\r\n0 - use fixed sealevel BARO value\r\n1 - Capture BARO at keyon, use to calculate boost"
	020020 Units            =""
	020100 Address          =0x116
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x4C24
	020005 Title            ="Frequency Out Mode"
	020011 DescSize         =0x1CE
	020010 Desc             ="00 off\r\n01 DSM 1G calculated from AirflowSource\r\n02 EVO8/DSM3G\r\n03 DSM 2G and 3000/Stealth\r\n04 Supra\r\n05 LS1 Car (aluminum MAF)\r\n06 LS1 Truck (Plastic MAF, with screen)\r\n07 LS6 (Plastic MAF, without screen)\r\n08 GN (Extender Extreme and Pro chips)\r\n09 GN (Extender chips)\r\n10 GN (Commander chips)\r\n11 GN (Standard style chips)\r\n12 LT1 (3\" aluminum MAF, Impala SS and other)\r\n13 LT1 (F and Y cars, 3.5\" aluminum MAF)\r\n30 Fixed frequency output to emulate Ford BAP"
	020020 Units            =""
	020100 Address          =0x117
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x3
	020300 ALDLObj1         =0x4
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x7FC4
	020005 Title            ="V Out1 Mode"
	020011 DescSize         =0x61
	020010 Desc             ="Select the mode of Analog Output 1\r\n0 - use Vout setpoint\r\n1 - Send analog timing signal to ECU "
	020020 Units            ="Select"
	020100 Address          =0x118
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x32CA
	020005 Title            ="V Out2 Mode"
	020011 DescSize         =0x61
	020010 Desc             ="Select the mode of Analog Output 2\r\n0 - use Vout setpoint\r\n1 - Send analog timing signal to ECU "
	020020 Units            ="Select"
	020100 Address          =0x119
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x249A
	020005 Title            ="AFR Source"
	020011 DescSize         =0xBE
	020010 Desc             ="Select connection and scaling of wideband input\r\n0 - none \r\n1-LC1  \r\n2-LM1 \r\n3-AEM, AFM-1, and other 10:1=0v...20:1=5v\r\n4-TechEdge 9:1=0v...19:1=5v\r\n5-Zeitronix ZT2, Non linear, 14.7:1=2.5v"
	020020 Units            ="Select"
	020100 Address          =0x11A
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
	020300 ALDLObj1         =0xD
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0xCA8
	020005 Title            ="Freq In Mode"
	020011 DescSize         =0xF1
	020010 Desc             ="Determines what signal is connected to Freq-In\r\n0-no MAF connected\r\n1-3\" LT1 MAF\r\n2-3.5\" LS1 MAF\r\n3-85mm Plastic MAF (no screen)\r\n4-Extreme Billet MAF\r\n5-GN Extreme MAFT\r\n6-85mm Truck MAF (with screen)\r\n7-3.5\" LT1 aluminum MAF (with screen)"
	020020 Units            =""
	020100 Address          =0x11B
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
	020300 ALDLObj1         =0x3
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6BDD
	020005 Title            ="Aux 1 mode"
	020011 DescSize         =0x76
	020010 Desc             ="determine the operating mode of the aux 1 input\r\ntriggering of aux functions, analog MAF input, \r\nor logging of data "
	020020 Units            =""
	020100 Address          =0x11C
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020300 ALDLObj1         =0x20
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x5761
	020005 Title            ="Main Scale"
	020011 DescSize         =0xA0
	020010 Desc             ="A tune setting that is added to the user tune.  The entire range is adjusted by this setting.  Can be used to adjust for larger injectors (as a starting point)"
	020020 Units            =""
	020100 Address          =0x160
	020200 Equation         =X*.5 - 64,TH|0|0|0|0|
	020300 ALDLObj1         =0xF
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x34FD
	020005 Title            ="Volts Out 1 Setpoint"
	020011 DescSize         =0x2F
	020010 Desc             ="Sets the voltage on Analog output 1 for mode 0"
	020020 Units            =""
	020100 Address          =0x161
	020200 Equation         =X*.01960784,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x23CD
	020005 Title            ="Volts Out 2 Setpoint"
	020011 DescSize         =0x2F
	020010 Desc             ="Sets the voltage on Analog output 2 for mode 0"
	020020 Units            =""
	020100 Address          =0x162
	020200 Equation         =X*(5/255),TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x4A07
	020005 Title            ="Afterstart enrichment"
	020011 DescSize         =0xA3
	020010 Desc             ="% of additional enrichment added upon engine start.  This enrichment is decreased slowly at idle, and quickly under load.  Usually only Mitsubishi cars need this."
	020020 Units            =""
	020100 Address          =0x163
	020200 Equation         =X * .1,TH|0|0|0|0|
	020300 ALDLObj1         =0x1E
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6F42
	020005 Title            ="Tune Load Point, Low"
	020011 DescSize         =0x35
	020010 Desc             ="The load that the Low Load User Tune is centered on."
	020020 Units            =""
	020100 Address          =0x164
	020200 Equation         =X *1.3,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x432E
	020005 Title            ="Tune Load Point, Mid"
	020011 DescSize         =0x35
	020010 Desc             ="The load that the Mid Load User Tune is centered on."
	020020 Units            =""
	020100 Address          =0x165
	020200 Equation         =X * 1.3,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x9ED
	020005 Title            ="Tune Load Point, High"
	020011 DescSize         =0x34
	020010 Desc             ="The load that the Hi Load User Tune is centered on."
	020020 Units            =""
	020100 Address          =0x166
	020200 Equation         =X * 1.3,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6381
	020005 Title            ="Freq Out Max"
	020011 DescSize         =0x3F
	020010 Desc             ="Max frequency output.  Set to 0 to disable frequency limiting."
	020020 Units            =""
	020100 Address          =0x167
	020200 Equation         =X*50,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
	020300 ALDLObj1         =0x4
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x5C8C
	020005 Title            ="Timing Monitor, Base Adjust"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x168
	020200 Equation         =(X-100) * .1,TH|0|0|0|0|
	020300 ALDLObj1         =0x23
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0xBB9
	020005 Title            ="Timing Monitor, Correction"
	020011 DescSize         =0x3C
	020010 Desc             ="Correction to make the high RPM Timing measurement correct."
	020020 Units            =""
	020100 Address          =0x169
	020200 Equation         =X *.01,TH|0|0|0|0|
	020300 ALDLObj1         =0x23
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6934
	020005 Title            ="AFR Tracking, Enable delay"
	020011 DescSize         =0x70
	020010 Desc             ="Once the enabling conditions for AFR Tracking are satisfied,  AFR tracking will enable after this delay expires"
	020020 Units            ="Seconds"
	020100 Address          =0x16A
	020200 Equation         =X * .1,TH|0|0|0|0|
	020300 ALDLObj1         =0x1E
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x7F1A
	020005 Title            ="FE Smoothing"
	020011 DescSize         =0x3D
	020010 Desc             ="Filter value for Flow Error.  Lower numbers make FE smoother"
	020020 Units            =""
	020100 Address          =0x16B
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020300 ALDLObj1         =0x12
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x4D39
	020005 Title            ="Boost control  TPS Spool"
	020011 DescSize         =0x4C
	020010 Desc             ="TPS must exceed this value before the boost control system can be activated"
	020020 Units            =""
	020100 Address          =0x1A0
	020200 Equation         =X/50,TH|0|0|0|0|
	020300 ALDLObj1         =0x4D2
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x473A
	020005 Title            ="Boost control RPM Spool"
	020011 DescSize         =0x46
	020010 Desc             ="RPM must exceed this before the boost control system can be activated"
	020020 Units            ="RPM"
	020100 Address          =0x1A1
	020200 Equation         =X*32,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
	020240 RangeHigh        =200.0000
	020300 ALDLObj1         =0x9
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x29E9
	020005 Title            ="Boost control TPS Start"
	020011 DescSize         =0xA5
	020010 Desc             ="Once boost control has switched from spool mode, the TPS must be greater than this value for the boost controller to increase the dutycycle to raise boost pressure."
	020020 Units            ="Volts"
	020100 Address          =0x1A2
	020200 Equation         =X * .02,TH|0|0|0|0|
	020300 ALDLObj1         =0x4D2
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x359C
	020005 Title            ="Boost control PSI Start"
	020011 DescSize         =0x59
	020010 Desc             ="Boost pressure at which the boost controller will switch from spool mode to control mode"
	020020 Units            ="PSI"
	020100 Address          =0x1A3
	020200 Equation         =X *.2,TH|0|0|0|0|
	020300 ALDLObj1         =0x24
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6E20
	020005 Title            ="Boost control DC% Start"
	020011 DescSize         =0x71
	020010 Desc             ="When the boost controller switches from spool mode to control mode, the solenoid dutycycle is set to this value "
	020020 Units            ="Percent"
	020100 Address          =0x1A4
	020200 Equation         =X *.4,TH|0|0|0|0|
	020300 ALDLObj1         =0x6
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x18D5
	020005 Title            ="Boost control PSI Set"
	020011 DescSize         =0x17
	020010 Desc             ="Desired boost pressure"
	020020 Units            ="PSI"
	020100 Address          =0x1A5
	020200 Equation         =X *.2,TH|0|0|0|0|
	020300 ALDLObj1         =0x24
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x1BA8
	020005 Title            ="Boost control PSI Aux"
	020011 DescSize         =0x38
	020010 Desc             ="Desired boost pressure when the Aux input is triggered."
	020020 Units            ="PSI"
	020100 Address          =0x1A6
	020200 Equation         =X *.2,TH|0|0|0|0|
	020300 ALDLObj1         =0x24
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x33EA
	020005 Title            ="Boost Control Gain"
	020011 DescSize         =0x5D
	020010 Desc             ="Speed at which the boost controller will change teh dutycycle to correct the boost pressure."
	020020 Units            =""
	020100 Address          =0x1A7
	020200 Equation         =X/2.50,TH|0|0|0|0|
	020300 ALDLObj1         =0x6
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x4D3A
	020005 Title            ="Boost Control DC% Start Aux"
	020011 DescSize         =0xB3
	020010 Desc             ="Initial dutycycle for begining boost control with AUX activated.  If boost control is active when AUX activates, the dutycycle will switch to this and boost control will resume. "
	020020 Units            ="Percent"
	020100 Address          =0x1A8
	020200 Equation         =X *.40,TH|0|0|0|0|
	020240 RangeHigh        =100.0000
	020300 ALDLObj1         =0x6
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x1644
	020005 Title            ="Boost Control Max RPM"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1A9
	020200 Equation         =X*32,TH|0|0|0|0|
	020300 ALDLObj1         =0x9
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x118C
	020005 Title            ="AFR Min TPS"
	020011 DescSize         =0x36
	020010 Desc             ="TPS must exced this value to enable the AFR tracking."
	020020 Units            =""
	020100 Address          =0x170
	020200 Equation         =X/50,TH|0|0|0|0|
	020300 ALDLObj1         =0x4D2
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x563B
	020005 Title            ="AFR Min RPM"
	020011 DescSize         =0x36
	020010 Desc             ="RPM must exceed this value to enable the AFR tracking"
	020020 Units            =""
	020100 Address          =0x171
	020200 Equation         =X*32,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
	020300 ALDLObj1         =0x9
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x32B7
	020005 Title            ="AFR Min Load"
	020011 DescSize         =0x31
	020010 Desc             ="Load must exceed this to enable the AFR tracking"
	020020 Units            =""
	020100 Address          =0x172
	020200 Equation         =X*(333/256),TH|0|0|0|0|
	020300 ALDLObj1         =0xB
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x3266
	020005 Title            ="AFR correction lean limit"
	020011 DescSize         =0x43
	020010 Desc             ="Max adjustment allowed by the AFR tracking to reduce fuel delivery"
	020020 Units            =""
	020100 Address          =0x173
	020200 Equation         =X/10,TH|0|0|0|0|
	020300 ALDLObj1         =0x14
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x3444
	020005 Title            ="AFR correction rich limit"
	020011 DescSize         =0x45
	020010 Desc             ="Max adjustment allowed by the AFR tracking to increase fuel delivery"
	020020 Units            =""
	020100 Address          =0x174
	020200 Equation         =X/10,TH|0|0|0|0|
	020300 ALDLObj1         =0x14
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6CAD
	020005 Title            ="AFR correction gain"
	020011 DescSize         =0x6F
	020010 Desc             ="Speed at which the AFR tracking will correct the fuel delivery to try to match the Target AFR (Air/Fuel Ratio)"
	020020 Units            =""
	020100 Address          =0x175
	020200 Equation         =X/2.5,TH|0|0|0|0|
	020300 ALDLObj1         =0x14
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0xD3E
	020005 Title            ="AFR Aux %"
	020011 DescSize         =0x55
	020010 Desc             ="Modification to AFR target when Aux in activated\r\nPositive values make target richer"
	020020 Units            =""
	020100 Address          =0x17D
	020200 Equation         =X*.5 -64,TH|0|0|0|0|
	020300 ALDLObj1         =0xD
%%END%%

%%TABLE%%
	000002 UniqueID         =0xAC
	040005 Title            ="VE table"
	040011 DescSize         =0x28
	040010 Desc             ="Engine efficiency, max at torque peak  "
	040100 Address          =0x0
	040200 ZEq              =.5 * X + 0.000000,TH|0|0|0|0|
	040203 XOutType         =0x2
	040304 YOutType         =0x2
	040210 DecimalPl        =0x1
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x11
	040305 Cols             =0xF
	040320 XUnits           ="RPM"
	040325 YUnits           ="MAP(Kpa)"
	040330 ZUnits           =""
	040350 XLabels          =00,400,800,1200,1600,2200,2800,3400,4000,4600,5200,5800,6400,7000,7600
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =00,20,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320
	040362 YLabelType       =0x2
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040425 YALDLObj         =0xB
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%TABLE%%
	000002 UniqueID         =0xB1
	040005 Title            ="AF User Tune Hi"
	040011 DescSize         =0x23
	040010 Desc             ="High Load fuel delivery adjustment"
	040100 Address          =0x120
	040200 ZEq              =0.5 * X - 64.000000,TH|0|0|0|0|
	040210 DecimalPl        =0x1
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0xE
	040320 XUnits           ="RPM"
	040325 YUnits           =""
	040330 ZUnits           =""
	040350 XLabels          =400,800,1200,1600,2200,2800,3400,4000,4600,5200,5800,6400,7000,7600
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =Percent
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%TABLE%%
	000002 UniqueID         =0x2975
	040005 Title            ="AF UserTune Mid"
	040011 DescSize         =0x22
	040010 Desc             ="Mid Load fuel delivery adjustment"
	040100 Address          =0x130
	040200 ZEq              =X*.5 -64,TH|0|0|0|0|
	040210 DecimalPl        =0x1
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0xE
	040320 XUnits           ="RPM"
	040325 YUnits           =""
	040330 ZUnits           ="%"
	040350 XLabels          =400,800,1200,1600,2200,2800,3400,4000,4600,5200,5800,6400,7000,7600
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =Percent
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%TABLE%%
	000002 UniqueID         =0x599
	040005 Title            ="AF User Tune Lo"
	040011 DescSize         =0x22
	040010 Desc             ="Low Load fuel delivery adjustment"
	040100 Address          =0x140
	040200 ZEq              =X*.5 -64,TH|0|0|0|0|
	040210 DecimalPl        =0x1
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0xE
	040320 XUnits           ="RPM"
	040325 YUnits           =""
	040330 ZUnits           ="%"
	040350 XLabels          =400,800,1200,1600,2200,2800,3400,4000,4600,5200,5800,6400,7000,7600
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =Percent
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%TABLE%%
	000002 UniqueID         =0x3F1C
	040005 Title            ="Aux Triggered tune"
	040011 DescSize         =0x3D
	040010 Desc             ="Fuel delivery change when the Aux input trigger is activated"
	040100 Address          =0x180
	040200 ZEq              =X*.5 -64,TH|0|0|0|0|
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0xE
	040320 XUnits           =""
	040325 YUnits           =""
	040330 ZUnits           ="%"
	040350 XLabels          =400,800,1200,1600,2200,2800,3400,4000,4600,5200,5800,6400,7000,7600
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =Percent
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x2A18
	020005 Title            ="TPS Enrichment"
	020011 DescSize         =0x3D
	020010 Desc             ="Amount of fuel delivery added when the throttle is opened.  "
	020020 Units            =""
	020100 Address          =0x150
	020200 Equation         =X * .01,TH|0|0|0|0|
	020300 ALDLObj1         =0x21
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x7DBD
	020005 Title            ="TPS Decay"
	020011 DescSize         =0x2E
	020010 Desc             ="Speed at which the TPS enrichment is removed."
	020020 Units            =""
	020100 Address          =0x151
	020200 Equation         =X*.01,TH|0|0|0|0|
	020300 ALDLObj1         =0x21
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x1249
	020005 Title            ="Throttle Body Size"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x152
	020200 Equation         =X,TH|0|0|0|0|
	020205 OutType          =0x2
	020210 DecimalPl        =0x1
	020300 ALDLObj1         =0x21
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x57BD
	020005 Title            ="TPS MAP Max"
	020011 DescSize         =0x3E
	020010 Desc             ="If MAP exceeds this value, TPS Response fuel is discontinued."
	020020 Units            =""
	020100 Address          =0x153
	020200 Equation         =X*(333/256),TH|0|0|0|0|
	020300 ALDLObj1         =0x21
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x3AAB
	020005 Title            ="MAP Enrichment"
	020011 DescSize         =0x46
	020010 Desc             ="Amount of fuel delivery added when the Manifold Pressure is rising.  "
	020020 Units            =""
	020100 Address          =0x154
	020200 Equation         =X * .01,TH|0|0|0|0|
	020300 ALDLObj1         =0x26
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x4E4A
	020005 Title            ="Boost Enrichment"
	020011 DescSize         =0x2E
	020010 Desc             ="MAP derived enrichment, for boost conditions."
	020020 Units            =""
	020100 Address          =0x155
	020200 Equation         =X*.01,TH|0|0|0|0|
	020300 ALDLObj1         =0x26
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x170C
	020005 Title            ="MAP TPS Min"
	020011 DescSize         =0x37
	020010 Desc             ="If TPS is below this value, MAP enrichment is disabled"
	020020 Units            ="Volts"
	020100 Address          =0x156
	020200 Equation         =X*5/250,TH|0|0|0|0|
	020300 ALDLObj1         =0x21
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x58AE
	020005 Title            ="MAP RPM Min"
	020011 DescSize         =0x22
	020010 Desc             ="Min RPM to enable MAP enrichment."
	020020 Units            =""
	020100 Address          =0x157
	020200 Equation         =X*32,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0xAA4
	020005 Title            ="MAF Limit TPS Threshold"
	020011 DescSize         =0x2C
	020010 Desc             ="Below this TPS, the Airflow will be limited"
	020020 Units            ="Volts"
	020100 Address          =0x158
	020200 Equation         =X/50,TH|0|0|0|0|
	020240 RangeHigh        =250.0000
	020300 ALDLObj1         =0x4D2
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x188E
	020005 Title            ="MAF Limit"
	020011 DescSize         =0x39
	020010 Desc             ="Limit of Speed Density airflow when TPS is below setting"
	020020 Units            =""
	020100 Address          =0x159
	020200 Equation         =x*.4,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x6FF1
	020005 Title            ="MAF Limit / KRPM"
	020011 DescSize         =0x70
	020010 Desc             ="Airflow per 1000 RPM limit.  If set to 10, the airflow will be limited to 10 at 1000 RPM,  20 at 2000 RPM, etc."
	020020 Units            ="Grams/Sec"
	020100 Address          =0x15A
	020200 Equation         =X*.1,TH|0|0|0|0|
	020300 ALDLObj1         =0x13
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x590A
	020005 Title            ="Part Throttle Tracking Idle TPS"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D0
	020200 Equation         =X/50,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x55A9
	020005 Title            ="Part Throttle Tracking Idle RPM"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D1
	020200 Equation         =X*32,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x54BD
	020005 Title            ="Part Throttle Tracking Idle A/F Ratio"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D2
	020200 Equation         =X/10,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x7426
	020005 Title            ="Part Throttle Tracking Cruise TPS"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D3
	020200 Equation         =X/50,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x277F
	020005 Title            ="Part Throttle Tracking Cruise RPM"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D4
	020200 Equation         =X*32,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x1ED7
	020005 Title            ="Part Throttle Tracking Cruise Load"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D5
	020200 Equation         =X*333/256,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x78E4
	020005 Title            ="Part Throttle Tracking Cruise A/F Ratio"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D6
	020200 Equation         =X/10,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0xFB4
	020005 Title            ="Part Throttle Tracking Lean Load"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D7
	020200 Equation         =X*333/256,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x51EA
	020005 Title            ="Part Throttle Tracking Lean Delay"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D8
	020200 Equation         =X/10,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0xDD2
	020005 Title            ="Part Throttle Tracking Lean A/F Ratio"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1D9
	020200 Equation         =X/10,TH|0|0|0|0|
%%END%%

%%CONSTANT%%
	000002 UniqueID         =0x108A
	020005 Title            ="Part Throttle Tracking Gain"
	020011 DescSize         =0x1
	020010 Desc             =""
	020020 Units            =""
	020100 Address          =0x1DA
	020200 Equation         =X/10,TH|0|0|0|0|
%%END%%

%%TABLE%%
	000002 UniqueID         =0x15A8
	040005 Title            ="Air Temp Correction"
	040011 DescSize         =0x99
	040010 Desc             ="Correction to fuel delivery for Intake Air Temperature. \r\nSpeed Density makes its own density calculation, this correction table is in addition to that."
	040100 Address          =0x190
	040200 ZEq              =X*.5 -64,TH|0|0|0|0|
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0x9
	040320 XUnits           ="degrees"
	040325 YUnits           =""
	040330 ZUnits           ="%"
	040350 XLabels          =-40.00,13.00,41.00,62.00,82.00,103.00,129.00,173.00,315.00
	040352 XLabelType       =0x1
	040354 XEq              =(null)
	040360 YLabels          =Pecent
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x10
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%TABLE%%
	000002 UniqueID         =0x4BF0
	040005 Title            ="Spark WOT"
	040011 DescSize         =0x58
	040010 Desc             ="Wide Open Throttle spark advance.  This value is sent to the ECU via analog signalling."
	040100 Address          =0x1B0
	040200 ZEq              =X/10 +15,TH|0|0|0|0|
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0xD
	040320 XUnits           ="RPM"
	040325 YUnits           =""
	040330 ZUnits           =""
	040350 XLabels          =2000,2500,3000,3500,4000,4500,5000,5500,6000,6500,7000,7500,8000
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =Degrees
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%

%%TABLE%%
	000002 UniqueID         =0x5CD9
	040005 Title            ="Spark Aux"
	040011 DescSize         =0x80
	040010 Desc             ="Wide Open Throttle spark advance when the aux input trigger is activated.  This value is sent to the ECU via analog signalling."
	040100 Address          =0x1C0
	040200 ZEq              =X/10 +15,TH|0|0|0|0|
	040203 XOutType         =0x2
	040304 YOutType         =0x4
	040230 RangeLow         =0.0000
	040240 RangeHigh        =255.0000
	040300 Rows             =0x1
	040305 Cols             =0xD
	040320 XUnits           ="RPM"
	040325 YUnits           =""
	040330 ZUnits           =""
	040350 XLabels          =2000,2500,3000,3500,4000,4500,5000,5500,6000,6500,7000,7500,8000
	040352 XLabelType       =0x2
	040354 XEq              =(null)
	040360 YLabels          =Degrees
	040362 YLabelType       =0x4
	040364 YEq              =(null)
	040400 XALDLObj         =0x9
	040660 XAxisMin         =1000.000000
	040670 XAxisMax         =1000.000000
	040760 YAxisMin         =1000.000000
	040770 YAxisMax         =1000.000000
%%END%%
